Bloodhound HRM03 Master Firmware v212

Expand / Collapse
 

Bloodhound HRM03 Master Firmware v212


This is Firmware Version 212 for the Bloodhound Gas Detector with an HRM03 Module at its heart.  
The HRM is the red, aluminum box in the center of the Bloodhound where all of the sensors and gas
chambers are located (you can see it when you open the lid of the Bloodhound for pump repairs, etc.).  
This version will *NOT* work in Bloodhounds with HRM modules other than HRM03.

HOW TO IDENTIFY HRM03 VS. HRM05 BLOODHOUNDS:
The HRM version of the Bloodhound is identified by the Serial Number on the Yellow Sticker near the
handle on the outside of the Bloodhound's case:
     HRM03 - The sticker will merely show something like "0123 iBall Instruments" or "0123".
     HRM05 - The sticker will show something like, "Enhanced Bloodhound 0123"

THIS FIRMWARE INCLUDES EVERYTHING IN V199, PLUS:
1)  BUG FIX:  There are a number of bug fixes in this firmware, including the "500-foot-per-hour-ROP
                     Speed Limit" fix.

2)  BUG FIX:  This version corrects the message flashed on the LCD screen when the unit is due or
                     overdue for repair.  In *any* shutdown mode, it asks the user to call support.

3)  FEATURE:  If your Bloodhound has been in the field for 6 months, the internal "odometer" will throw
                     a visual alarm and display a text message on the screen indicating it's time to schedule
                     a service call for the unit.  If it's been in the field for more than 7 months, the unit will be
                     put into "SHUTDOWN" mode immediately as overdue for service. 

                     NOTE 1:  This occurs when upgrading a unit's firmware as well if that unit's field-time
                                    exceeds either of these thresholds.

                     NOTE 2:  If after upgrading your unit with this firmware, you encounter this problem,
                                   please call Bloodhound support at 303.459.4660 to either schedule a return for
                                   regular maintenance, or to get a one-time extension to complete a field-based
                                   job before returning for service.

INSTRUCTIONS ON HOW TO INSTALL THIS FIRMWARE IN YOUR BLOODHOUND CAN BE FOUND HERE:
http://www.bhkb.org/kb2/KnowledgebaseArticle50061.aspx


Rate this Download:

Download File


IB_PGM_212.zip IB_PGM_212.zip (28.29 KB, 35 views)

Add Your Comments


Name: *
Email Address:
Web Address:
   
  
 
 
   
Verification Code:
*
 

Details
Last Modified:11/10/2013 8:40:56 AM

Last Modified By: syonker

Type: RELEASE

Article not rated yet.

Article has been viewed 103 times.

Options